Dalap DAN -small duct fan with ball bearings, tapered
Combination name | Code | EAN | Availability | Price VAT excl. | Preis VAT incl. | Add to cart |
---|---|---|---|---|---|---|
DAN
The small and compact Dalap DAN duct fan is used for efficient air extraction from residential and non-residential premises. These include bathrooms, toilets, kitchens, small offices and other spaces that need to be ventilated regularly. Thanks to the ball bearing motor and the tapered body, the fan can be easily installed in both horizontal and vertical duct orientations.
Advantages of the Dalap DAN duct fan
- - motor with ball bearings enabling horizontal and vertical installation
- - up to 40,000 hours of continuous operation
- - tapered body for easy connection to ducts
- - easy connection to the mains
- - small, compact dimensions
- - compatible with ducting and grilles
DAN 12V
The small and compact Dalap DAN 12V duct fan is used for efficient extraction of air from residential and non-residential premises, which need to be ventilated regularly. Thanks to the 12 V motor, it is safe to place the fan in a very humid environment and in places where there is a higher risk of contact with water. These are bathrooms, toilets, kitchens, small offices and other similar spaces. Thanks to the tapered body, the fan can be easily installed in the duct.
Attention
Dalap DAN 12 is designed for 12 V alternating voltage (AC). This fan is not suitable for 12 V DC operation.
Advantages of the Dalap DAN 12V duct fan
- - 12V motor for safe use in very humid environments
- - tapered body for easy connection to ducts
- - easy connection to the mains using a transformer
- - small, compact dimensions
- - compatible with ducting and grilles
Model | Dimensions (mm) | ||||
---|---|---|---|---|---|
A | E | Ød | ØD | Downloads | |
100 | 80 | 30 | 100 | 103 | Detail |
125 | 87 | 30 | 125 | 128 | Detail |
150 | 101 | 35 | 150 | 153 | Detail |
Model | Voltage (V) at 50 Hz | Power consumption (W) | Current (A) | r.p.m. | Maximum air capacity (m3/h) | Sound pressure level at 3m (dB(A)) | Weight (kg) | Static pressure (Pa) | Graphs |
---|---|---|---|---|---|---|---|---|---|
Dalap 100 DAN | 230 | 14 | 0,06 | 2400 | 107 | 35 | 0,4 | 46 | Detail |
Dalap 125 DAN | 230 | 18 | 0,08 | 2400 | 190 | 36 | 0,5 | 56 | Detail |
Dalap 150 DAN | 230 | 20 | 0,09 | 2400 | 280 | 37 | 0,6 | 60 | Detail |
Dalap 100 DAN 12V | 12 | 14 | 1,33 | 2400 | 107 | 35 | 0,4 | 46 | Detail |
Dalap 125 DAN 12V | 12 | 18 | 1,5 | 2400 | 190 | 36 | 0,5 | 56 | Detail |
Dalap 150 DAN 12V | 12 | 20 | 1,67 | 2400 | 280 | 37 | 0,6 | 60 | Detail |