Series EPP EX ATEX

Explosion Proof Certified Centrifugal fans to extract air and fumes through medium/long sized ducts in compliance with ATEX Directive 84/9/EEC effective from July 1st 2003 in EU.

Combination name Code EAN Availability Price VAT excl. Preis VAT incl. Add to cart
Dalap EPP 310 EX ATEX 4 poles 3620 4250622627871 ON REQUEST 1,269.24 € 1,510.40 €
shopping_cart
Dalap EPP 320 EX ATEX 4 poles 3622 8009278280253 ON REQUEST 1,326.55 € 1,578.60 €
shopping_cart
Dalap EPP/400V 310 EX ATEX 4 poles 3621 4250622627895 ON REQUEST 976.34 € 1,161.85 €
shopping_cart
Dalap EPP/400V 320 EX ATEX 4 poles 3623 8009278280260 ON REQUEST 1,090.97 € 1,298.25 €
shopping_cart
Dalap EPP/400V 330 EX ATEX 4 poles 3624 4250622627918 ON REQUEST 1,277.73 € 1,520.50 €
shopping_cart
Dalap EPP/400V 340 EX ATEX 4 poles 3625 8009278280314 ON REQUEST 1,477.23 € 1,757.90 €
shopping_cart
Dalap EPP/400V 350 EX ATEX 4 poles 3627 4250622627932 ON REQUEST 1,644.92 € 1,957.45 €
shopping_cart
Dalap EPP/400V 360 EX ATEX 4 poles 3628 8009278280321 2024-05-10 1,761.68 € 2,096.40 €
shopping_cart
Dalap EPP/400V 370 EX ATEX 4 poles 3629 4250622627956 2024-04-05 2,920.29 € 3,475.15 €
shopping_cart
Dalap EPP/400V 380 EX ATEX 4 poles 3630 4250622627963 1 pc. 3,109.29 € 3,700.05 €
shopping_cart

APPLICATION

Explosion Proof Certified Centrifugal fans to extract air and fumes through medium/long sized ducts in compliance with ATEX Directive 84/9/EEC effective from July 1st 2003 in EU. Suitable for applications in commercial and industrial environments where the risk of explosion is high and where  the surrounding atmosphere contains gas, vapours or highly inflammable steam. The whole product and not just the electrical parts, has been certified by CESI Institute with CESI n°03 ATEX 250 certificate.

Fan group II, cat. 2 for gases, construction safety C, max surface temp. T3 (200°C); Classified for zones 1 and 2. This approval has required specific safety tests and proper examinations on products to verify how the adopted solutions have satisfied the essential Directive requirements.

DESIGN

Steel plated frame protected by an epoxy-based anticorrosive paint and aluminium centrifugal impeller statically and dynamically balanced.

MOTOR

- ball bearing class F insulation motor IP55 protected.

- Max temperature of extracted air: 40°C

- Reversibility: all models

- Reference Standards: EN 13463-1; EN 13463-5; EN 14986

MOUNTING

The fan is installed on the wall surface by means of a square mounting plate.Models EPP 350, 360, 370 and 380: mounted on rigid base support to make installation easier.


CUSTOMS CODE: 84145940

EX ATEX_EN

EN_Safety instruction

EX ATEX_CZ

CZ_Bezpečnostní pokyny

EX ATEX_DE

DE_Sicherheitshinweise

EX ATEX_ES

ES_Instrucciones de seguridad

EX ATEX_FR

FR_Instructions de sécurité

EX ATEX_HU

HU_Biztonsági utasítások

EX ATEX_PL

PL_Instrukcje bezpieczeństwa

EX ATEX_SK

SK_Bezpečnostné pokyny

EPP+EPF

Declaration of conformity

Model

Voltage (V) at 50 HzPower consumption (W)

Current (A)


230V   400V

r.p.m.

Maximum air capacity (m3/h)Sound pressure level at 2m (dB(A))Weight (kg)

Graphs

Dalap EPP 310 EX ATEX 4 poles 230 200 1 - 1400 500 64 13,0 Detail
Dalap EPP 320 EX ATEX 4 poles 230 250 1,5 - 1400 720 67 14,0 Detail
Dalap EPP/400V 310 EX ATEX 4 poles 230/400 200 1 0,59 1400 500 64 13,0 Detail
Dalap EPP/400V 320 EX ATEX 4 poles 230/400 250 1,75 1 1400 720 67 14,0 Detail
Dalap EPP/400V 330 EX ATEX 4 poles 230/400 400 1,9 1,1 1400 1500 70 21,0 Detail
Dalap EPP/400V 340 EX ATEX 4 poles 230/400 1000 3,5 2 1400 1900 73 31,0 Detail
Dalap EPP/400V 350 EX ATEX 4 poles 230/400 1400 4 2,31 1400 2900 76 37,0 Detail
Dalap EPP/400V 360 EX ATEX 4 poles 230/400 1900 5,7 3,3 1400 4100 80 44,0 Detail
Dalap EPP/400V 370 EX ATEX 4 poles 230/400 2500 8,7 5 1400 5600 84 67,0 Detail
Dalap EPP/400V 380 EX ATEX 4 poles 230/400 4500 15,6 9 1400 9100 88 91,0 Detail

ModelDimensions (mm)
ADEFGLDownload
Dalap EPP 310 EX ATEX 4 poles 139 127 122 94 91 - Detail
Dalap EPP 320 EX ATEX 4 poles 172 146 150 112 117 - Detail
Dalap EPP/400V 310 EX ATEX 4 poles 139 127 122 94 91 - Detail
Dalap EPP/400V 320 EX ATEX 4 poles 172 146 150 112 117 - Detail
Dalap EPP/400V 330 EX ATEX 4 poles 209 147 188 141 139 - Detail
Dalap EPP/400V 340 EX ATEX 4 poles 250 178 222 164 162 - Detail
Dalap EPP/400V 350 EX ATEX 4 poles 290 210 260 194 192 232 Detail
Dalap EPP/400V 360 EX ATEX 4 poles 290 210 260 194 192 232 Detail
Dalap EPP/400V 370 EX ATEX 4 poles 334 230 250 221 210 325 Detail
Dalap EPP/400V 380 EX ATEX 4 poles 429 300 370 249 280 325 Detail

ModelDimensions (mm)
B

ØC

HYKIMNOØb
Dalap EPP 310 EX ATEX 4 poles 108 180 - 63 42 242 378 - - -
Dalap EPP 320 EX ATEX 4 poles 128 200 - 63 45 242 399 - - -
Dalap EPP/400V 310 EX ATEX 4 poles 108 180 - 63 42 242 378 - - -
Dalap EPP/400V 320 EX ATEX 4 poles 128 200 - 63 45 242 399 - - -
Dalap EPP/400V 330 EX ATEX 4 poles 163 250 - 71 40 242 423 - - -
Dalap EPP/400V 340 EX ATEX 4 poles 194 250 - 80 45 259 468 - - -
Dalap EPP/400V 350 EX ATEX 4 poles 225 315 245 80 50 259 503 120 149 11
Dalap EPP/400V 360 EX ATEX 4 poles 225 315 245 90 50 300 544 120 155 11
Dalap EPP/400V 370 EX ATEX 4 poles 244 355 350 100 50 354 625 170 173 11
Dalap EPP/400V 380 EX ATEX 4 poles 315 400 350 112 62 358 669 170 194 11

ModelDimensions (mm)
PQRSTUØa
Dalap EPP 310 EX ATEX 4 poles 135 135 114 114 88 90 8,2
Dalap EPP 320 EX ATEX 4 poles 152 152 126 126 105 105 8,2
Dalap EPP/400V 310 EX ATEX 4 poles 135 135 114 114 88 90 8,2
Dalap EPP/400V 320 EX ATEX 4 poles 152 152 126 126 105 105 8,2
Dalap EPP/400V 330 EX ATEX 4 poles 191 191 165 165 134 134 8,2
Dalap EPP/400V 340 EX ATEX 4 poles 225 235 195 206 161 170 8,2
Dalap EPP/400V 350 EX ATEX 4 poles 255 255 225 225 191 194 8,2
Dalap EPP/400V 360 EX ATEX 4 poles 255 255 225 225 191 194 8,2
Dalap EPP/400V 370 EX ATEX 4 poles 284 305 254 275 213 244 10,2
Dalap EPP/400V 380 EX ATEX 4 poles 310 360 280 330 241 295 9