Vents VUT EH series

The unit with a heat exchanger and an electric heater is a heat recovery device and is one of the energy saving components used in buildings and premises.

The unit enables continuous air exchange by means of mechanical ventilation in private residences, offices, hotels, cafes, conference rooms, etc.

Combination name Code EAN Availability Price VAT excl. Preis VAT incl. Add to cart
Vents VUT 500 EH 22520 4823059378519 2 pcs. 2,382.06 € 2,834.65 €
shopping_cart
Vents VUT 2000 EH 22521 4824032006320 1 pc. 4,094.12 € 4,872.00 €
shopping_cart
Vents SF 438x215x48 (G4) 2165 4824032293454 ON REQUEST 39.45 € 46.95 €
shopping_cart
Vents SF 438x215x48 (F7) 2166 4250622649316 ON REQUEST 45.38 € 54.00 €
shopping_cart
Vents SF 780x273x48 (G4) 2168 4824032293232 2024-05-03 75.13 € 89.40 €
shopping_cart
Vents SF 780x273x48 (F7) 2167 4824032294512 ON REQUEST 87.86 € 104.55 €
shopping_cart
APPLICATION

- Air handling units VUT EH with electric heater is the complete air handling unit designed to provide both
  supply and exhaust ventilation with air filtering and heat recovery. The exhaust air energy is used to heat up
  the supply fresh air through the heat exchanger.

- Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, coarse dust,
  soot and oil particles, sticky substances, fibrous materials, pathogens or any other harmful substances.

- All the models are designed for connection with Ø 150, 315 mm round ducts.

- The unit is a component unit and is not designed for independent operation.


DESIGN

operating logic

- Warm stale extract air from the room flows through the air ducts to the unit, where it is filtered, then air flows
  through the heat exchanger and is exhausted outside by the extract fan through the air ducts.
- Clean cold air from outside is moved by the supply fan to the unit, where from it is directed to the supply filter.
- Then filtered air flows through the heat exchanger and moves to the room through the air ducts.
- Heat energy of warm extract air is transferred to clean intake fresh air from outside and warms it up.
- Heat recovery minimizes thermal energy losses, energy demand and operating costs for supply air heating
  accordingly.

- The unit is a framework construction that includes six rigidly fixed 25 mm (for the VUT 500 EH unit) and 50 mm
  (for the VUT 2000 EH unit) thick sandwich panels.

  The three-layer sandwich panels are made of two galvanized steel sheets, internally filled with thermal- and sound-insulated
  layer of mineral wool.

- The air supply and exhaust unit is equipped with quick-release access panels with special gaskets for easy repair and
  maintenance.

- The unit is designed for indoor application with the ambient temperature ranging from +1 °C up to +40 °C and relative humidity
  up to 80%.

- The unit is classified as a class I electric appliance.

- The power and ground cables are routed to the terminal block through sealed lead-ins.

- Hazardous parts access and water ingress protection standard:

»Unit motors - IP 44
»Unit assembly connected to air ducts - IP 22

- The unit must be grounded!


EQUIPMENT

VUT EH a range of compact energy saving air handling units (AHU) equipped with supply and exhaust centrifugal fans,
  cross-flow heat exchanger, electric heater and air filters.

» Filters ⇒ two incorporated G4 panel filters for extract air ventilation are supplied with the unit.
» Fans ⇒ The unit is equipped with supply and exhaust centrifugal double-inlet fans with forward curved blades
                 and built-in thermostat with automatic restart.
            ⇒ The electric motors and impellers are dynamically balanced in two planes.
            ⇒ The ball-bearings used with motors are designed for at least 40 000 hours operation and are
                 maintenance-free.
» Heat exchanger ⇒ The heat exchangers have high efficiency and are made of polystyrol.
                                ⇒ The unit is also equipped with the drain pan for condensate drainage.
» Heater ⇒ The electric heater at outlet from the heat exchanger is designed for warming up of supply air up
                     to the set level if heat recovery is not enough to attain the set supply air temperature.


CONTROL

» Automation and control system
                ⇒ The unit incorporates an integrated automation and control system with a multi-functional control panel
                     with LCD display.
                ⇒ The standard delivery set includes 10 m connection cable for connection to the remote control panel.
                ⇒ The unit has the freezing protection function to prevent the heat exchanger freezing by means of
                     actuating the bypass damper.
                     As the temperature sensor warns of the freezing danger, the bypass air damper is opened and the intake air
                     is directed through the air duct beside the heat exchanger.
                     As the heat exchanger is warmed the supply air temperature rises up to the set level while passing through
                     the heater.
                     Meanwhile the warm extract air warms up the heat exchanger. After the freezing danger
                     is no longer imminent, the bypass damper shuts the bypass duct and the unit reverts to the standard
                     operation mode.

» VUT EH control and protection functions
                ⇒ control from the control panel: switching on/off, speed selection, timer, faults
                ⇒ maintaining the set room temperature by the sensor on the control panel – smooth heating capacity control
                ⇒ three-speed fan speed control (low-medium-high)
                ⇒ unit operation according to daily and week schedule (timer adjustable from the control panel)
                ⇒ safe start-up/shutdown of the fans
                ⇒ electric heater overheating protection by the temperature sensor installed in the supply air duct and by two
                     overheating thermostats
                ⇒ filter clogging control by engine filter time


MOUNTING

- The unit is designed for indoor mounting.

- Access for the unit servicing and filter cleaning is from the side panels on the left from supply air side.

- While mounting the unit provide the correct condensate collection and drainage.

- The unit is suspended to the mounting surface through the threaded rod fixed inside the threaded dowel.

- The unit is also suitable also for mounting to a horizontal mounting surface.

- While mounting the unit provide the minimum required access to the unit for maintenance and repair.

- The required minimum distances from the unit to the wall is shown in User's manual.


OPTIONS

- For attenuation of sound generated by the fans it is recommended to install the duct silencer from inside before the unit.

- For vibration absorbing it is recommended to install the flexible anti-vibration connectors on both sides of the unit.

ModelDimensions (mm)
ØDBB1B2B3HH1H2H3LL1L2Weight [kg]Downloads
Vents VUT 500 EH 150 497 403 248 348 554 - 111 230 954 996 1057 49 Detail
Vents VUT 2000 EH 315 842 581 320 520 814 947 201 394 1345 1394 1447 96 Detail
ModelDimensions (mm)
ABCDownloads
Vents SF 438x215x48 (G4)
(for VUT 500 EH)
438 215 48 Detail 
Vents SF 438x215x48 (F7)
(for VUT 500 EH)
438 215 48 Detail 
Vents SF 780x273x48 (G4)
(for VUT 2000 EH)
780 273 48 Detail 
Vents SF 780x273x48 (F7)
(for VUT 2000 EH)
780 273 48 Detail 
Model

Voltage [V]
/
Frequency [Hz]

Maximum
fan
power
[W]
Maximum
fan
current
[A]
Elelctric
heater
power
[kW]
Elelctric
heater
current
[A]
Total
unit
power
[kW]
Total
unit
current
[A]
Maximum
air
capacity
[m³/h]
Rotation
speed

[1/min]
Vents VUT 500 EH 1∼230/50-60 2 items×150 2 items×0,66 3 13 3,3 14,32 500 1100
Vents VUT 2000 EH 3∼400/50-60 2 items×650 2 items×2,84 18 26 19,3 31,7 2200 1150

Model

Noise level
3m
[dB(A)]
Transported
air
temperature
[°C]
Casing
material

Insulation


Filters


Heat
recovery
efficiency
[%]
Heat
exchanger
type

Heat
exchanger
material

Power
graphs

Vents VUT 500 EH 28-47 -25 up to +50
aluzinc

25 [mm]
mineral wool

G4
up to 88
cross-flow

polystyrene
Detail
Vents VUT 2000 EH 65 -25 up to +40 up to 77 Detail

ModelFilter materialFiltration classColor
Vents SF 438x215x48 (G4)
(for VUT 500 EH)
synthetic fibers G4 white
Vents SF 438x215x48 (F7)
(for VUT 500 EH)
synthetic fibers F7 white
Vents SF 780x273x48 (G4)
(for VUT 2000 EH)
synthetic fibers G4 white
Vents SF 780x273x48 (F7)
(for VUT 2000 EH)
synthetic fibers F7 white